OceanStor Data Storage
OceanStor Pacific 9920 Scale-out Storage
OceanStor Pacific 9920 is a performance-optimized all-flash scale-out storage product. Each 2 U chassis houses 1 node and 25 disk slots that support palm-sized NVMe SSDs with a capacity of up to 61.44 TB. • FlashLink® and AI Fabric network acceleration enable a single system to meet the performance needs of millions of virtual machines. • Multiple data redundancy ratios are available. OceanStor Pacific 9920 is ideal for applications such as virtualization/cloud resource pools, databases, HPC, and big data analytics.

Specifications · OceanStor Pacific 9920
| Scenario | Unstructured Data |
|---|---|
| System Architecture | Fully symmetric scale-out architecture |
| Storage Access Protocol | NFS, SMB, POSIX, MPI-IO, HDFS, Amazon S3, and FTP |
| Raw Capacity per Chassis | 23.04 TB ~ 1536TB |
| Height per Chassis | 2U |
| Number of Nodes per Chassis | 1 |
| Max. Number of Primary Storage Disks per Node | 25 |
| Primary Storage Disk Type | Palm-sized NVMe SSDs |
| Processors per Node | 2 x Huawei Kunpeng 920 Processors |
| Max. Memory per Node | 512 GB |
| Number of System Disks per Node | 2 x 480 GB SATA SSDs |
| Front-End Service Network Type* | • 25GE or 100GE TCP/IP • 100GE RoCE • 100Gb/s or 200Gb/s InfiniBand |
| Storage Network Type | • 100GE TCP/IP • 25GE or 100GE RoCE • 100Gb/s or 200Gb/s InfiniBand |
| Data Redundancy Protection Mechanism | EC: N + M (M is 2, 3, or 4) |
| Data Self-Healing | Automatic concurrent data reconstruction at 2 TB per hour |
| Key Features | • Elastic EC • SmartQuota • SmartTier • SmartQoS • SmartEqualizer • SmartMulti-Tenant • SmartEncryption • SmartAuditlog • HyperLock(WORM) • HyperSnap • HyperReplication(A) • SmartIndexing • Recycle Bin • SmartInterworking • DIF • Object Versioning* • SmartTakeover* • SmartCompression • HyperGeoMetro* • HyperGeoEC* • SmartCache • SmartSync |
| Storage Management Software | DeviceManager and eService |
| Chassis Dimensions (H x W x D) | 86.1 mm x 447 mm x 830 mm |
| Max. Weight per Chassis (with Disks) | ≤ 35 kg |
| Operating Temperature | 5°C to 35°C |
| Operating Humidity | 8% RH to 90% RH (non-condensing) |
Specifications · #2
| Scenario | Structured Data |
|---|---|
| System Architecture | Fully symmetric scale-out architecture |
| Storage Access Protocol | SCSI, iSCSI, and OpenStack Cinder |
| Raw Capacity per Chassis | 7.68 TB ~ 768 TB |
| Height per Chassis | 2U |
| Number of Nodes per Chassis | 1 |
| Max. Number of Primary Storage Disks per Node | 25 |
| Primary Storage Disk Type | Palm-sized NVMe SSDs |
| Processors per Node | 2 x Kunpeng 920 processors |
| Max. Memory per Node | 512 GB |
| Number of System Disks per Node | 2 x 480 GB SATA SSDs |
| Front-End Service Network Type* | • 10 GE or 25 GE TCP/IP • 25 GE or 100 GE RoCE • 100 Gbit/s InfiniBand |
| Storage Network Type | • 10 GE or 25 GE TCP/IP • 25 GE or 100 GE RoCE • 100 Gbit/s InfiniBand |
| Data Redundancy Protection Mechanism | • EC: N + M (M is 2, 3, or 4) • Multi-copy: 3-copy mode |
| Data Self-Healing | Automatic concurrent data reconstruction at 4 TB per hour |
| Key Features | • Omni-Dataverse • SmartThin • SmartDedupe & SmartCompression • SmartQoS • SmartEncryption • SmartAuditlog • HyperSnap • HyperClone • HyperMetro • HyperReplication(S) • HyperReplication(A) • MultiPool • DIF • SmartMove • InfoRevive • Ransomware Protection |
| Storage Management Software | DeviceManager and eService |
| Chassis Dimensions (H x W x D) | 86.1 mm x 447 mm x 830 mm |
| Max. Weight per Chassis (with Disks) | ≤ 35 kg |
| Operating Temperature | 5°C to 35°C |
| Operating Humidity | 5% to 90% RH (non-condensing) |
Specifications
*Please contact us for more information.
Documents
In the same family
OceanStor Pacific 9926High-Density Capacity: 2 PB/2 U raw capacity. Powered by 2:1 compression, 4PB/2 U capacity.
OceanStor Pacific 9928Ultimate Performance: DTOE NIC offloading, unique Distributed Parallel Client (DPC), and adaptation to hybrid workloads combine to achieve collaborative optimization for optimal performance.